Capabilities and Capacities |
Throughput: Application Control (AVC)
|
450 Mbps |
Throughput: Application Control (AVC) and IPS
|
250 Mbps |
Maximum concurrent sessions |
100,000 |
Maximum New Connections per second |
10,000 |
Supported applications |
More than 3,000 |
URL categories |
80+ |
Number of URLs categorized |
More than 280 million |
Centralized configuration, logging, monitoring, and reporting |
Multi-device Cisco Security Manager (CSM) and Cisco Firepower Management Center |
On-Device Management |
ASDM (version 7.3 or higher required) |
Features and Capacities |
Stateful inspection throughput (maximum) |
1 Gbps |
Stateful inspection throughput (multiprotocol) |
500 Mbps |
Triple Data Encryption Standard/Advanced Encryption Standard (3DES/AES) VPN throughput |
175 Mbps |
Users/nodes |
Unlimited |
IPsec site-to-site VPN peers |
100 |
Cisco AnyConnect Plus/Apex VPN maximum simultaneous connections |
100 |
Virtual interfaces (VLANs) |
50 |
Security contexts (included; maximum) |
2; 5 |
High availability |
Active/Active and Active/Standby |
Integrated Wireless Access Point
(See Cisco AP 702 datasheet for WiFi technical details)
|
N/A |
Expansion slot
|
N/A |
User-accessible Flash slot
|
No |
USB 2.0 ports
|
USB port type ‘A’, High Speed 2.0 |
Integrated I/O
|
8 x 1GE |
Expansion I/O
|
N/A |
Dedicated management port
|
Yes (To be shared with FirePOWER Services), 10/100/1000 |
Serial ports
|
1 RJ-45 and Mini USB console |
Solid-state drive
|
80 GB mSata |
Memory
|
8 GB |
System flash
|
8 GB |
System bus
|
Multibus architecture |
Operating Parameters
|
Temperature |
32 to 104°F (0 to 40 °C) |
Relative humidity |
90 percent noncondensing |
Altitude |
Designed and tested for 0 to 10,000 ft (3050 m) |
Acousticnoise |
41.6 A-weighted decibels (dBA) type, 67.2 dBA max |
Non-operating Parameters |
Temperature |
-13 to 158ºF (-25 to 70ºC) |
Relative humidity |
10 to 90 percent noncondensing |
Altitude |
Designed and tested for 0 to 15,000 ft (4572 m) |
Power Input (per power supply) |
AC range line voltage |
External, 90 to 240 volts alternating current (VAC) |
AC normal line voltage |
91 to 240 VAC |
AC current |
0.25AC amps |
AC frequency |
50/60 Hz |
Dual-power supplies |
None |
DC domestic line voltage |
N/A |
DC international line voltage |
N/A |
DC current |
N/A |
Output |
Steady state |
12V @ 3.0A |
Maximum peak |
12V @ 5.0A |
Maximum heat dissipation |
205 Btu/hr |
Form factor |
1 rack unit (RU), 19-in. rack-mountable |
Dimensions (H x W x D) |
1.72 x 17.2 x 11.288 in. (4.369 x 43.688 x 28.672 cm) |
Weight (with AC power supply) |
8 lb (3 kg) |